PLC input output module
[tmpmela_list][list_item icon=”fa fa-check-circle” color=”#b53b8c”]Multiple inputs[/list_item][list_item icon=”fa fa-check-circle” color=”#b52f88″]Output coils[/list_item][list_item icon=”fa fa-check-circle” color=”#b52f88″]Auxiliary relays[/list_item][/tmpmela_list]
Real examples
[tmpmela_list][list_item icon=”fa fa-check-circle” color=”#b53b8c”]Switches as an input.[/list_item][list_item icon=”fa fa-check-circle” color=”#b52f88″] Machine signal as an input.[/list_item][list_item icon=”fa fa-check-circle” color=”#b52f88″]Output coil to control 230V load.[/list_item][/tmpmela_list]
Fundamentals of ladder diagram
| INPUTS | Normally close | Normally open |
|---|---|---|
| OUTPUTS | Normally close | Normally open |
| Output itself work as a input | - | - |
| Analog input. | - | - |
| Timer as an input. | - | - |
| Counter as an input. | - | - |
Real examples
TIMER
Explaining following timer with its time control, set and reset function.
[tmpmela_list][list_item icon=”fa fa-check-circle” color=”#ca69a9″]On-Delay Timer[/list_item][list_item icon=”fa fa-check-circle” color=”#b53b8c”]Equal/Unequal ON/OFF 1 Timer[/list_item][list_item icon=”fa fa-check-circle” color=”#b52f88″]Equal/Unequal ON/OFF 2 Timer[/list_item][list_item icon=”fa fa-check-circle” color=”#b52f88″]Delayed Impulse Timer[/list_item][list_item icon=”fa fa-check-circle” color=”#be4997″]Leading Edge Impulse 2 Timer[/list_item][/tmpmela_list]
[tmpmela_list][list_item icon=”fa fa-check-circle” color=”#b53b8c”]Off-Delay Timer[/list_item][list_item icon=”fa fa-check-circle” color=”#b52f88″] Equal/Unequal OFF/ON 1 Timer[/list_item][list_item icon=”fa fa-check-circle” color=”#b52f88″]Equal/Unequal OFF/ON 2 Timer[/list_item][list_item icon=”fa fa-check-circle” color=”#b52f88″]Leading Edge Impulse 1 Timer[/list_item][list_item icon=”fa fa-check-circle” color=”#b52f88″]Trailing Edge Impulse 1 Timer[/list_item][/tmpmela_list]
Counters
[tmpmela_list][list_item icon=”fa fa-check-circle” color=”#ca69a9″]Desired Display Units[/list_item][list_item icon=”fa fa-check-circle” color=”#b53b8c”] Number of pulses[/list_item][list_item icon=”fa fa-check-circle” color=”#b52f88″]Decimal point position[/list_item][list_item icon=”fa fa-check-circle” color=”#b52f88″]Comparison of counters[/list_item][/tmpmela_list]
Analog Signal
[tmpmela_list][list_item icon=”fa fa-check-circle” color=”#ca69a9″]Take base voltage[/list_item][list_item icon=”fa fa-check-circle” color=”#b53b8c”] Set reference voltage[/list_item][list_item icon=”fa fa-check-circle” color=”#b52f88″]Voltage comparison.[/list_item][list_item icon=”fa fa-check-circle” color=”#b52f88″]Process on multiple analog input.[/list_item][/tmpmela_list]
| Duration | The duration of this workshop will be three consecutive days, with six hour session each day in a total of eightteen hours properly divided into theory and hands on sessions. |
|---|---|
| Eligibility | Level workshop so there is no prerequisites. Anyone interested, can join this workshop. |
| Fee | Rs. 350/-(inclusive of all Taxes) per participant. * This fee include workshop training, government taxes and other human resources charges. |
| Note | Minimum students’ strength is 60 |